Search results for "Digital subtraction angiography"
showing 10 items of 30 documents
Chronic Thromboembolic Pulmonary Hypertension: Pre- and Postoperative Assessment with Breath-hold MR Imaging Techniques
2004
To evaluate the potential of breath-hold magnetic resonance (MR) imaging techniques in morphologic and functional assessment of patients with chronic thromboembolic pulmonary hypertension (CTEPH) before and after surgery.Thirty-four patients with CTEPH were examined before and after pulmonary thromboendarterectomy (PTE). For morphologic assessment, contrast material-enhanced MR angiography was used; for assessment of hemodynamics, velocity-encoded gradient-echo sequences and cine gradient-echo sequences along the short axis of the heart were performed. Contrast-enhanced MR angiography was compared with selective digital subtraction angiography (DSA) for depiction of central thromboembolic m…
Comparison of contrast-enhanced MR angiography to intraarterial digital subtraction angiography for evaluation of peripheral arterial occlusive disea…
2010
Purpose To evaluate the efficacy and safety of 0.1 mmol/kg gadodiamide administration for contrast-enhanced magnetic resonance angiography (CE-MRA) in detecting hemodynamically relevant main stenosis (ie, ≥50% or occlusion) of aortoiliac arteries. Materials and Methods In a multicenter, phase 3, controlled study, patients with suspected or proven peripheral arterial occlusive disease (PAOD) underwent CE-MRA with administration of gadodiamide. Intraarterial digital subtraction angiography (IA-DSA) was used as the reference. The study was approved by all Institutional Review Boards or Institutional Ethic Committees prior to commencement of patient recruitment and written informed consent was …
Noninvasive assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-con…
2013
Background— Right heart catheterization is the gold standard for assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension. To date, MRI has not been able to produce precise measurements of mean pulmonary arterial pressure (mPAP). The purpose of the study was to create a model for estimating mPAP and pulmonary vascular resistance in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-contrast MRI (PC-MRI) and to correlate the results with simultaneously acquired, invasive catheter-based measurements (simultaneously measured mPAP) and with right heart catheterization measurements. Methods and Results— A tota…
A multicenter, site-independent, blinded study to compare the diagnostic accuracy of contrast-enhanced magnetic resonance angiography using 1.0M gado…
2007
Abstract Purpose Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0 M gadobutrol compared to intraarterial DSA in body arteries. Materials and methods In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. Results The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6–90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (N…
Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial
2007
OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…
MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarte…
2007
Purpose To compare gadobenate dimeglumine (Gd-BOPTA)–enhanced MR angiography (i.e., contrast-enhanced MRA [CE-MRA]) of the pedal vasculature with selective digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). Materials and Methods A total of 22 patients with PAOD were prospectively examined at 1.5T. For contrast enhancement, 0.1 mmol/kg body weight of Gd-BOPTA were applied. MRA consisted of dynamic imaging with acquisition of six consecutive data sets. Acquisition time for each data set was 24 seconds, voxel size was 1.0 × 1.0 × 1.3 mm3. A total of 20 out of 22 patient underwent selective DSA, two patients fine-needle DSA. DSA and MRA were per…
Kontrastverstärkte MR-Angiographie abdomineller Gefäßean einem 1.0 T-System*
2000
Purpose To evaluate the efficacy of breath-hold, three-dimensional, contrast-enhanced magnetic resonance angiography with a 1.0 T system for imaging the abdominal vessels in comparison to conventional arteriography (CA). Methods The abdominal aorta and visceral arteries were studied in 54 patients (60 examinations) on a 1.0 T scanner using an ultrafast gadolinium-enhanced gradient-echo sequence with the following parameters: TR/TE = 3.8/1.4 ms, flip angel 25 degrees, matrix 198 x 256, field 380-420 mm, pixel size 1.9 x 1.48 mm2, slice thickness 1.5-2.5 mm, acquisition time 22-26 sec. Individual circulation times were determined by a test bolus before each MR angiography. Conventional arteri…
Minimally Invasive Monitoring of Chronic Central Venous Catheter Patency in Mice Using Digital Subtraction Angiography (DSA)
2015
PLoS ONE 10(6), e0130661 (2015). doi:10.1371/journal.pone.0130661
DOSE-RELATED EFFICACY OF A CONTINUOUS INTRACISTERNAL NIMODIPINE TREATMENT ON CEREBRAL VASOSPASM IN THE RAT DOUBLE SUBARACHNOID HEMORRHAGE MODEL
2009
Objective Intracisternal continuous therapy is a concept in the treatment of cerebral vasospasm after subarachnoid hemorrhage. The purpose of the current study was to investigate the effect of intracisternal nimodipine after induced vasospasm. Methods Sixty-five male Wistar rats were randomized into 4 groups: the control sham-operated group, the control subarachnoid hemorrhage-only group, and the treatment groups receiving 5 or 10 microL/hour of intracisternal nimodipine continuously for 5 days via subcutaneously implanted Alzet osmotic pumps (Durect Corp., Cupertino, CA). Vasospasm was analyzed 5 days later by means of digital subtraction angiography. Morphological examination of the brain…
Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair
2019
Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…